Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Acta Ophthalmol ; 2023 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-38126128

RESUMO

PURPOSE: To compare detection rates of microaneurysms (MAs) on high-speed megahertz optical coherence tomography angiography (MHz-OCTA), fluorescein angiography (FA) and colour fundus photography (CF) in patients with diabetic retinopathy (DR). METHODS: For this exploratory cross-sectional study, MHz-OCTA data were acquired with a swept-source OCT prototype (A-scan rate: 1.7 MHz), and FA and CF imaging was performed using Optos® California. MA count was manually evaluated on en face MHz-OCTA/FA/CF images within an extended ETDRS grid. Detectability of MAs visible on FA images was evaluated on corresponding MHz-OCTA and CF images. MA distribution and leakage were correlated with detectability on OCTA and CF imaging. RESULTS: 47 eyes with severe DR (n = 12) and proliferative DR (n = 35) were included. MHz-OCTA and CF imaging detected on average 56% and 36% of MAs, respectively. MHz-OCTA detection rate was significantly higher than CF (p < 0.01). The combination of MHz-OCTA and CF leads to an increased detection rate of 70%. There was no statistically significant association between leakage and MA detectability on OCTA (p = 0.13). For CF, the odds of detecting leaking MAs were significantly lower than non-leaking MAs (p = 0.012). Using MHz-OCTA, detection of MAs outside the ETDRS grid was less likely than MAs located within the ETDRS grid (outer ring, p < 0.01; inner ring, p = 0.028). No statistically significant difference between rings was observed for CF measurements. CONCLUSIONS: More MAs were detected on MHz-OCTA than on CF imaging. Detection rate was lower for MAs located outside the macular region with MHz-OCTA and for leaking MAs with CF imaging. Combining both non-invasive modalities can improve MA detection.

2.
Ophthalmol Retina ; 7(12): 1042-1050, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37517798

RESUMO

PURPOSE: To evaluate the association of microvascular lesions on ultrawidefield (UWF) color fundus (CF) images with retinal nonperfusion (RNP) up to the midperiphery on single-capture widefield (WF) OCT angiography (OCTA) in patients with diabetic retinopathy (DR). DESIGN: Cross-sectional study. SUBJECTS: Seventy-five eyes of 50 patients with mild to severe nonproliferative DR (NPDR) and proliferative DR (PDR) were included in this analysis. METHODS: ETDRS level and presence of predominantly peripheral lesions (PPLs) were assessed on UWF-CF images acquired with a Zeiss Clarus 700. Single-capture 65°-WF-OCTA was performed using a PlexElite prototype (Carl Zeiss Meditec, Inc.). A custom grid consisting of a central ETDRS grid extended by 2 rings reaching up to the midperiphery was overlaid to subdivide retinal areas visible on WF-OCTA en face images. Retinal nonperfusion was measured in each area and in total. Nonperfusion index (NPI) was calculated from total RNP. On UWF-CF images, the number of microaneurysms, hemorrhages, neovascularizations, and areas with intraretinal microvascular abnormalities (IRMAs) were evaluated using the same grid. MAIN OUTCOME MEASURES: Association of diabetic lesions with RNP was calculated using Spearman correlations (rs). RESULTS: Median RNP on WF-OCTA was 0 mm2 (0-0.9), 4.9 mm2 (1.9-5.4), 23.4 mm2 (17.8-37), and 68.4 mm2 (40.8-91.7) in mild, moderate, and severe NPDR and PDR, respectively. We found a statistically significant correlation (P < 0.01) of overall RNP (rs = 0.96,) and NPI (rs = 0.97) on WF-OCTA with ETDRS level. Number of grid-fields affected by IRMAs on CF images was highly associated with NPI (rs = 0.86, P < 0.01). Intraretinal microvascular abnormalities and RNPs had similar topographic distributions with high correlations in affected areas. Eyes with PPLs (n = 43 eyes, 57%) on CF images had a significantly higher NPI (P = 0.014) than eyes without PPLs. CONCLUSION: The combination of UWF-CF imaging and single-capture WF-OCTA allows precise and noninvasive analysis of the retinal vasculature up to the midperiphery in patients with DR. The presence and extent of IRMAs on CF images may serve as an indicator for underlying RNP, which is more pronounced in eyes with PPLs. FINANCIAL DISCLOSURE(S): Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Humanos , Estudos Transversais , Angiofluoresceinografia/métodos , Retina/patologia , Retinopatia Diabética/diagnóstico , Retinopatia Diabética/complicações , Imagem Multimodal
3.
Opt Lett ; 48(11): 3079-3082, 2023 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-37262285

RESUMO

Swept-source optical coherence tomography (SS-OCT) demonstrates superior performance in comparison to spectral domain OCT with regard to depth ranging. The main driver of cost for SS-OCT systems is, however, the price of the source. Here we show a low-cost alternative swept source that uses a thermally tuned vertical-cavity surface-emitting laser (VCSEL) at 850 nm. Its center wavelength can be tuned by adjusting the operating temperature through modulation of the injection current. At 2 kHz sweep rate, the depth range of the system was 5 cm, with a sensitivity roll-off of under -3 dB across this range. The system achieved a sensitivity of 97 dB with a sample beam power of 0.3 mW and an axial resolution of 50 µm in air. To demonstrate the system performance in vivo, an eye of a healthy volunteer was measured, and full-eye scans were acquired at 25 and 50 kHz from the cornea to the retina. Based on our results, we believe that this technology can be used as a cost-effective alternative OCT for point-of-care diagnostics.

4.
Sci Rep ; 13(1): 8713, 2023 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-37248309

RESUMO

Diabetic retinopathy (DR), a pathologic change of the human retinal vasculature, is the leading cause of blindness in working-age adults with diabetes mellitus. Optical coherence tomography angiography (OCTA), a functional extension of optical coherence tomography, has shown potential as a tool for early diagnosis of DR through its ability to visualize the retinal vasculature in all spatial dimensions. Previously introduced deep learning-based classifiers were able to support the detection of DR in OCTA images, but require expert labeling at the pixel level, a labor-intensive and expensive process. We present a multiple instance learning-based network, MIL-ResNet,14 that is capable of detecting biomarkers in an OCTA dataset with high accuracy, without the need for annotations other than the information whether a scan is from a diabetic patient or not. The dataset we used for this study was acquired with a diagnostic ultra-widefield swept-source OCT device with a MHz A-scan rate. We were able to show that our proposed method outperforms previous state-of-the-art networks for this classification task, ResNet14 and VGG16. In addition, our network pays special attention to clinically relevant biomarkers and is robust against adversarial attacks. Therefore, we believe that it could serve as a powerful diagnostic decision support tool for clinical ophthalmic screening.


Assuntos
Diabetes Mellitus , Retinopatia Diabética , Adulto , Humanos , Retinopatia Diabética/diagnóstico por imagem , Retinopatia Diabética/patologia , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Vasos Retinianos/patologia , Diagnóstico Precoce , Diabetes Mellitus/patologia
5.
Biomed Opt Express ; 14(2): 846-865, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36874504

RESUMO

Intraoperative optical coherence tomography is still not overly pervasive in routine ophthalmic surgery, despite evident clinical benefits. That is because today's spectral-domain optical coherence tomography systems lack flexibility, acquisition speed, and imaging depth. We present to the best of our knowledge the most flexible swept-source optical coherence tomography (SS-OCT) engine coupled to an ophthalmic surgical microscope that operates at MHz A-scan rates. We use a MEMS tunable VCSEL to implement application-specific imaging modes, enabling diagnostic and documentary capture scans, live B-scan visualizations, and real-time 4D-OCT renderings. The technical design and implementation of the SS-OCT engine, as well as the reconstruction and rendering platform, are presented. All imaging modes are evaluated in surgical mock maneuvers using ex vivo bovine and porcine eye models. The applicability and limitations of MHz SS-OCT as a visualization tool for ophthalmic surgery are discussed.

6.
Br J Ophthalmol ; 2022 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-36376062

RESUMO

AIM: To assess the detection rate of retinal neovascularisation (NV) in eyes with proliferative diabetic retinopathy (PDR) using widefield optical coherence tomography angiography (WF-OCTA) in comparison to ultrawidefield fluorescein angiography (UWF-FA). METHODS: Single-capture 65°-WF-OCTA-imaging was performed in patients with NV at the disc or elsewhere (NVE) detected on UWF-FA using a modified PlexElite system and B-scans were examined for blood flow signals breaching the internal limiting membrane. Sensitivity of WF-OCTA and UWF colour fundus (UWF-CF) photography for correct diagnosis of PDR was determined and interdevice agreement (Fleiss' κ) between WF-OCTA and UWF-FA for detection of NV in the total gradable area and each retinal quadrant was evaluated. RESULTS: Fifty-nine eyes of 41 patients with PDR detected on UWF-FA were included. Sensitivity of detecting PDR on WF-OCTA scans was 0.95 in contrast to 0.78 on UWF-CF images. Agreement in detecting NVE between WF-OCTA and UWF-FA was high in the superotemporal (κ=0.98) and inferotemporal (κ=0.94) and weak in the superonasal (κ=0.24) and inferonasal quadrants (κ=0.42). On UWF-FA, 63% of NVEs (n=153) were located in the temporal quadrants with 93% (n=142) of them being detected on WF-OCTA scans. CONCLUSION: The high reliability of non-invasive WF-OCTA imaging in detecting PDR can improve clinical examination with the potential to replace FA as a single diagnostic tool.

7.
Biomed Opt Express ; 12(11): 6762-6779, 2021 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-34858679

RESUMO

Ocular aberrometry is an essential technique in vision science and ophthalmology. We demonstrate how a phase-sensitive single mode fiber-based swept source optical coherence tomography (SS-OCT) setup can be employed for quantitative ocular aberrometry with digital adaptive optics (DAO). The system records the volumetric point spread function at the retina in a de-scanning geometry using a guide star pencil beam. Succeeding test-retest repeatability assessment with defocus and astigmatism analysis on a model eye within ± 3 D dynamic range, the feasibility of technique is demonstrated in-vivo at a B-scan rate of >1 kHz in comparison with a commercially available aberrometer.

8.
Neurophotonics ; 7(3): 035004, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-32855993

RESUMO

Significance: Amyloid-beta ( A - ß ) plaques are pathological protein deposits formed in the brain of Alzheimer's disease (AD) patients upon disease progression. Further research is needed to elucidate the complex underlying mechanisms involved in their formation using label-free, tissue preserving, and volumetric techniques. Aim: The aim is to achieve a one-to-one correlation of optical coherence tomography (OCT) data to histological micrographs of brain tissue using 1060-nm swept source OCT. Approach: A - ß plaques were investigated in ex-vivo AD brain tissue using OCT with the capability of switching between two magnifications. For the exact correlation to histology, a 3D-printed tool was designed to generate samples with parallel flat surfaces. Large field-of-view (FoV) and sequentially high-resolution volumes at different locations were acquired. The large FoV served to align the OCT to histology images; the high-resolution images were used to visualize fine details. Results: The instrument and the presented method enabled an accurate correlation of histological micrographs with OCT data. A - ß plaques were identified as hyperscattering features in both FoV OCT modalities. The plaques identified in volumetric OCT data were in good agreement with immunohistochemically derived micrographs. Conclusion: OCT combined with the 3D-printed tool is a promising approach for label-free, nondestructive, volumetric, and fast tissue analysis.

9.
Opt Lett ; 44(4): 967-970, 2019 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-30768032

RESUMO

We demonstrate a synthetic subaperture-based angle-independent Doppler flow calculation, using a line field spectral domain optical coherence tomography system. The high speed of the system features a high phase stability over the volume, which is necessary to apply synthetic subapertures in the aperture plane. Thus, the flow component for each subaperture can be reconstructed in postprocessing. Capillary phantom and in vivo retinal imaging experiments were performed to validate and demonstrate angle-independent Doppler flow calculation.


Assuntos
Fluxo Sanguíneo Regional , Vasos Retinianos/diagnóstico por imagem , Vasos Retinianos/fisiologia , Tomografia de Coerência Óptica , Humanos , Imageamento Tridimensional , Imagens de Fantasmas
10.
J Biophotonics ; 12(4): e201800382, 2019 04.
Artigo em Inglês | MEDLINE | ID: mdl-30652423

RESUMO

A forward imaging endoscope for optical coherence tomography angiography (OCTA) featuring a piezoelectric fiber scanner is presented. Imaging is performed with an optical coherence tomography (OCT) system incorporating an akinetic light source with a center wavelength of 1300 nm, bandwidth of 90 nm and A-line rate of 173 kHz. The endoscope operates in contact mode to avoid motion artifacts, in particular, beneficial for OCTA measurements, and achieves a transversal resolution of 12 µm in air at a rigid probe size of 4 mm in diameter and 11.3 mm in length. A spiral scan pattern is generated at a scanning frequency of 360 Hz to sample a maximum field of view of 1.3 mm. OCT images of a human finger as well as visualization of microvasculature of the human palm are presented both in two and three dimensions. The combination of morphological tissue contrast with qualitative dynamic blood flow information within this endoscopic imaging approach potentially enables improved early diagnostic capabilities of internal organs for diseases such as bladder cancer.


Assuntos
Angiografia/instrumentação , Endoscopia/instrumentação , Tomografia de Coerência Óptica/instrumentação , Artefatos , Dedos/diagnóstico por imagem , Humanos , Movimento
11.
Biomed Opt Express ; 9(4): 1871-1892, 2018 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-29675326

RESUMO

Imaging of the human retina with high resolution is an essential step towards improved diagnosis and treatment control. In this paper, we introduce a compact, clinically user-friendly instrument based on swept source optical coherence tomography (SS-OCT). A key feature of the system is the realization of two different operation modes. The first operation mode is similar to conventional OCT imaging and provides large field of view (FoV) images (up to 45° × 30°) of the human retina and choroid with standard resolution. The second operation mode enables it to optically zoom into regions of interest with high transverse resolution using adaptive optics (AO). The FoV of this second operation mode (AO-OCT mode) is 3.0° × 2.8° and enables the visualization of individual retinal cells such as cone photoreceptors or choriocapillaris. The OCT engine is based on an akinetic swept source at 1060 nm and provides an A-scan rate of 200 kHz. Structural as well as angiographic information can be retrieved from the retina and choroid in both operational modes. The capabilities of the prototype are demonstrated in healthy and diseased eyes.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...